Ir al contenido principal

Guía de autoinstalación de cocinas

Índice


Componentes para la instalación

SmartSense offers multiple configurations to provide optimum monitoring in your specific environment. The assets you have chosen to monitor will determine which components have been included in your system. Follow the instructions for your specific configuration.

Kitchen

Supervisión de la temperatura

The image below shows SmartSense device install locations.

Screen_Shot_2021-06-07_at_10.56.58_AM.png



A) Z Sensors

Z Sensors are typically used in environments that require radio communication through thick metal or concrete. Z Sensors also include a wireless and detachable screen.

B) B2 Sensors

B2 Sensors leave an ultra-small footprint, are completely wireless, and are NSF-certified sensors for placement in food contact areas.

C) Handheld Probe

The wireless handheld probe is used to complete digital HACCP SOPs and other repeatable tasks. These features are covered in the HACCP user guide found here.

D) Gateways

All of our gateway products are plug-and-play. Once installed in an area with good cellular coverage, they will automatically pair with sensors and report to the dashboard.


Wireless Signal Interference

Note: Back-of-house (BOH) kitchen layouts will vary.

Screen_Shot_2021-06-07_at_10.58.49_AM.png
Screen_Shot_2021-06-07_at_10.58.45_AM.png


The diagrams above are only a guide and are not intended to represent your exact kitchen layout. Please use the diagrams as a reference tool when choosing the best possible location to mount your gateway.

Obstruction

Obstruction Severity

Obstruction Defined

Wood/wood paneling

Low

Inside a wall or hollow door

Drywall

Low

Inside walls

Half wall

Low

Partitions

Clear glass

Low

Windows

People

Medium

High-volume traffic areas that have considerable foot traffic

Ceramic tile

Medium

Walls

Concrete blocks

Medium/High

Outer/inner wall construction

Mirrors

High

Mirror or reflective glass

Metals

High

Hood vent system/metal doors/overhead doors

Dead zones

High

Halls/corridors

Electrical

High

Panel/circuit breaker boxes

Microwaves

High

Industrial microwave ovens


SmartSense Sensor Installation Best Practices

  1. Begin sensor installations using the included installation sheet.

    • After each sensor is installed, record the device ID and asset name on the installation sheet.

  2. Make sure to check that devices are reporting AS THEY'RE INSTALLED for all devices.

  3. Please consider the following information to ensure a successful installation:

    • Sensors should always be attached to a secure and permanent surface.

    • This is applicable in walk-in units where you should never install it on a moveable rack or hanging above the door.


Instalación de la pasarela BZ

  1. Saque la pasarela BZ de su embalaje.

    helpjuice_production_uploads_upload_image_3604_direct_1607107702562-Screen_Shot_2020-12-04_at_1.32.50_PM__2_.png
  2. Enchufa el BZ Gateway a una toma de corriente específica para cargarlo. La toma de corriente no debe estar conectada a un interruptor. El BZ Gateway debe permanecer siempre conectado a la red eléctrica durante su funcionamiento normal.

    helpjuice_production_uploads_upload_image_3604_direct_1607107792462-IMG_0848.jpeg

    Nota: Es posible que su pasarela BZ deba cargarse durante 30 minutos antes de pasar al paso 4.

  3. Enchufa el adaptador de corriente al BZ Gateway, ejerciendo la fuerza suficiente para que quede bien ajustado. Tira suavemente del cable del adaptador de corriente para asegurarte de que la conexión sea firme. La alimentación de CA se indica mediante el LED azul situado junto al conector del adaptador de corriente.

    cable de alimentación.jpg
  4. Utilice el Modo Buscador de Señal (SFM) en la Pasarela BZ para determinar una ubicación de instalación con la mejor intensidad de señal celular.

    buscador de señal mode.png



    a) To enter Signal Finder Mode, hold the power button for 3-4 seconds then release the button.

    b) A white LED will flash repeatedly to indicate you are in Signal Finder Mode.

  5. Para lograr la mejor conectividad, mueva la puerta de enlace BZ alrededor de la ubicación de instalación hasta que el LED blanco comience a parpadear rápidamente (un LED rojo parpadeante indica una señal celular deficiente). La intensidad máxima de la señal se representa con un parpadeo del LED blanco cada 200 ms (cuanto más rápido parpadee el LED blanco, mayor será la intensidad de la señal celular).

  6. Una vez encontrada una buena ubicación, pulse y suelte rápidamente el botón de encendido para salir del modo Buscador de señales.

  7. Coloque las tiras de velcro suministradas en las cuatro esquinas de la parte posterior de la pasarela BZ.

  8. Si se instala sobre metal, paredes de hormigón o cualquier superficie porosa que pueda retener humedad, instale la pasarela BZ utilizando el soporte y los tornillos de montaje (SKU: TM-GW-VZ-VZW-C, disponible bajo pedido).

  9. Instale la puerta de enlace BZ en una superficie de pared limpia, a dos metros del suelo, presionando el dispositivo firmemente contra la pared para asegurarse de que el velcro se adhiere completamente.

  10. Una vez instalada la pasarela BZ, utiliza soportes para cables y bridas para organizar el cableado de forma ordenada y evitar que se enganche o dañe la pasarela BZ.

  11. Consulte la guía de estado LED incluida a continuación para confirmar que la puerta de enlace BZ se está comunicando.

Note: SmartSense does not condone the use of drills or screws for any device installation. Customers self-installing do so at their own risk.


Once you are done installing the BZ Gateway, you will need to install the BZ Gateway Mounting Bracket.

  1. Saque la pasarela BZ y el soporte de montaje de sus respectivos embalajes.

  2. Inserte los tornillos de mariposa incluidos en la parte posterior de la puerta de enlace BZ.

    BZ_Pasarela_Soporte_de_montaje-04.png
  3. Utilizando el soporte de montaje como guía, marque y taladre dos orificios en la pared.

    • Tenga en cuenta la superficie que está perforando y lo que puede haber detrás de ella.

    • Estos pasos deben completarse sólo después de confirmar la disponibilidad de energía, la señal celular y la salud de los informes del dispositivo para todos los sensores asociados.

      BZ_Gateway_Montaje_Bracket-01.png
  4. Con un martillo, introduzca los anclajes en los orificios hasta que queden a ras de la pared.

  5. Instale el soporte de montaje en la pared utilizando los tornillos incluidos.

    BZ_Pasarela_Montaje_Bracket-03.png
  6. Fije la puerta de enlace BZ al soporte insertándola desde la parte superior y deslizándola hacia abajo para asentar la puerta de enlace BZ en la muesca del soporte.

    BZ_Pasarela_Montaje_Bracket-05.png
  7. El soporte de montaje también se puede instalar en un bastidor o estante utilizando bridas de cremallera.

    BZ_Pasarela_Montaje_soporte-06.png

GUÍA DE REFERENCIA DE LED

GUÍA DE REFERENCIA DE LED

GUÍA DE REFERENCIA DE LED

GUÍA DE REFERENCIA DE LED

Estado

LED blanco

LED rojo

Descripción

Encendido

-

1 flash LED blanco largo

Última carga correcta

-

1 destello corto de LED blanco cada 30s

Batería baja

-

1 parpadeo corto del LED blanco seguido de 1 parpadeo corto del LED rojo, cada 30s

Batería baja que impide la comunicación

-

-

1 parpadeo corto del LED rojo, cada 30s

Señal de móvil baja

--

1 parpadeo corto del LED blanco seguido de 2 parpadeos cortos del LED rojo, cada 30s

Sin señal de móvil

-

--

2 parpadeos cortos del LED rojo, cada 30s

Póngase en contacto con el servicio de asistencia de SmartSense

-

---

3 parpadeos cortos del LED rojo, cada 30s

Fallo de hardware

-

•••••••

LED rojo intermitente continuo


Instalación del sensor B2

Screen_Shot_2022-01-28_at_11.11.18_AM.png


Su sensor SmartSense B2 llega apagado.

  1. Para encender su Sensor B2, mantenga pulsado el botón durante aproximadamente 3 segundos hasta que el LED verde empiece a parpadear y suéltelo inmediatamente.

  2. El LED verde permanecerá encendido durante 5 segundos para indicar que está encendido y emitiendo.

  3. En condiciones normales de funcionamiento, estos son los únicos momentos en los que se iluminará el LED.

  4. Una vez encendido, el sensor B2 no se puede apagar.

  5. Seleccione un lugar que sea el más cálido de su nevera, a menudo cerca de la parte superior y cerca de la puerta.

  6. Use the included zip tie to mount the B2 Sensor. The zip tie should be threaded through the mounting loop at the top of the sensor and attached securely to a mounting point so that the sensor is hanging vertically and facing toward the door of your case. Ensure the B2 Sensor is mounted out of the way of daily operations and products.

  7. If a suitable mounting point does not exist, use a zip tie anchor by removing the cover of the double stick tape and adhering the anchor to your preferred location. Attach the B2 Sensor to the anchor.

B2 Sensors are used to monitor temperatures in environments like warming trays, grill drawers, and reach-in coolers.

Grill Drawer Installation

  1. To install in a grill drawer, open the top drawer and remove any pans.

  2. Using zip ties or double-sided velcro tape included in the sensor package, peel one side of the tape film off and place it on the back of the B2 Sensor.

  3. If using velcro, using a clean towel, clean the backside of the drawer face where you will be mounting the B2 Sensor (clean with warm water only, and dry thoroughly).

  4. Peel the remaining film off of the double-sided velcro square, now on the B2 Sensor, and mount the B2 Sensor on the backside of the drawer face while applying pressure for 10 seconds.

  5. Ensure that all devices installed are not at risk of impeding or becoming damaged due to daily operations.

    grill.jpeg


Reach-In Cooler Installation

  1. To install the B2 Sensor in a reach-in cooler, clear a space in the middle of the cooler near the door.

  2. Using zip ties, attach the B2 Sensor to the wire rack so that it is hanging vertically. Trim any excess plastic from the zip tie.

    reach-in_freezer.jpeg
  3. Ensure that all devices installed are not at risk of impeding or becoming damaged due to daily operations.

    Note: SmartSense does not condone the use of drills or screws for any device installations. Customers self-installing do so at their own risk.


Z Sensor Installation - Walk-In Coolers & Freezers

  1. Install the Z Sensor in the walk-in cooler or freezer near the door on the inside of the unit, about 6 feet up. Z Sensors should be placed at least 3 feet away from the door for consistent product readings.

  2. The Z Sensor should be placed as close to the product as possible.

  3. Either attach the Z Sensor using its magnetic back or zip tie it to a permanent fixture (i.e. wire rack). Generally, magnets are the best attachment method, but zip ties can be used in cases with wire racks if necessary.

    Screen_Shot_2021-05-25_at_8.39.01_AM.png
  4. Make sure the Z Sensors are installed in a spot where they will not impede daily operations or be at risk of becoming damaged (i.e. front of a high wire rack or underside of the shelf).

  5. Press the Z Sensor's power button to turn it on.

    Note: SmartSense does not condone the use of drills or screws for any device installation. Customers self-installing do so at their own risk.


Pairing a Display Screen with a Z Sensor

  1. Your Z Sensor should have arrived from the factory pre-paired. Quickly hit the power button on the wireless screen to search for its paired sensor. If this doesn't work or if the Z Sensor and Z Screen become un-paired, follow steps 2-6.

  2. Mantén pulsado el botón de encendido de la pantalla Z hasta que oigas dos pitidos distintos y, a continuación, suéltalo. Es posible que tengas que acercarte la pantalla Z a la oreja para oír los pitidos. Si sigues sin oírlos, intenta mantener pulsado el botón durante unos 6 segundos y suéltalo.

    1595360752670-Z_Screen_Onlt.png
  3. La pantalla Z debe mostrar un mensaje indicando que ha entrado en "Modo Emparejamiento".

    1595360815197-PG9-1.png
  4. Coge el sensor Z y pulsa y suelta rápidamente el botón de encendido. Las luces se encenderán y luego se apagarán. La luz verde empezará a parpadear, indicando que el sensor está buscando una conexión.

    1595360829046-PG9-2_copy.png
  5. You'll know the Z Screen and Z Sensor are paired when the Z Screen displays the temperature. Confirm the Z Screen is paired with the correct Z Sensor by matching the 20-digit number located on the Z Screen and the barcode sticker on the side of the Z Sensor.

    1595360842500-PG9-3_copy.png
  6. You can switch from a Fahrenheit display to Celsius by holding the Z Screen power button for 3 seconds, or until you hear two sets of beeps, and let go.


Installing a NIST Probe

  1. To install or replace a NIST, Humidity, or Glycol probe, unscrew the protective cap or existing probe in a counterclockwise direction and discard it.

    original-1.png
  2. Para conectar una nueva sonda NIST, alinee la flecha de la sonda NIST con la flecha del mismo puerto del que acaba de retirar la sonda antigua. Hay cinco clavijas en el sensor Z y cinco orificios en la sonda NIST que se corresponden.

    original-2.png
  3. Gently screw the NIST probe into the same port in a clockwise direction. Do not use excessive force, as this can damage the pins.

    original-3.png

    Nota: Las sondas NIST deben instalarse en el puerto 1 a menos que las patillas del puerto 1 se hayan doblado, en cuyo caso la sonda NIST puede instalarse en el puerto 2.


Verifying System Connectivity

  1. Locate your dashboard instructions for detailed login directions and how to view sensor temperature data.

  2. All sensors should be reading like the image below.

    bev-frdge.png
  3. If a question mark appears next to a sensor, it is not communicating with the gateway.

    • The gateway position should be adjusted.

    • Remember the gateway needs to be centrally located between the cook-line and walk-in/reach-in cooler door.


Troubleshooting Tips

If your SmartSense Gateway is not reporting, please confirm the following:

  1. Confirm the proper LED light sequence based on gateway type.

  2. The gateway's power cable is not cut or damaged (if so, you will need to purchase a replacement).

  3. The gateway's power cable is plugged in and the power source has not been compromised.

  4. The gateway is mounted securely and high up on the wall in an upright position. If the gateway is located behind connectivity-blocking objects (metal walls or other units), this can affect connectivity.

If your SmartSense Sensors are not reporting properly, please confirm the following:

  1. All gateways are powered on and reporting properly. Please ensure this first before troubleshooting sensors.

  2. Confirm the sensor type (you can learn more about sensor types here).

  3. If you are troubleshooting B2 Sensors, confirm that the sensor is located in a clear line of sight to a gateway - ensure the gateway is not installed behind commonly closed doors, walls, piping, etc. B2 Sensor will report at all times and does not have an on/off switch. You can remove the B2 Sensor from the unit and place it near the gateway to confirm it is still reporting properly. If the B2 Sensor still does not report, please contact the SmartSense Support team.

  4. If you are troubleshooting Z Sensors, confirm that the Z Sensor is powered on by pressing the power button on the front face of the sensor.


Completing Your Install

Before you finish:

  1. Record all device names/locations with their respective sensor serial numbers on the installation sheet (download here).

  2. Are all sensors securely and properly installed?

  3. Are all gateways installed central to the sensors, high on the wall, unobstructed, and out of the way of daily operations?

  4. Are all sensors currently reporting (have they reported in the last ten minutes) AS THEY'RE INSTALLED?

  5. Ensure you have left your workspace clean and free of packaging materials.

¿Te ha servido esta respuesta?